Ultrasound

(multiple units)

Sonos 7500, Philips Medical

  • Cardiac & Vascular Calculation Packages 
  • Live 3D Echo 
  • Live xPlane Imaging
  • Color Doppler, Color Angio & Colorization 
  • Fusion Harmonic Imaging 
  • Contrast Imaging 
  • Spectral Steered PW & CW Doppler
  • Lateral Gain Control (LGC)
  • M-Mode
  • Cine and Zoom/RES (ROI) 
  • ECG
  • High Resolution Non-Interlaced Monitor
  • DICOM
  • The system is equipped with omniplane 3D, 15MHz, 12MHz, 8MHz, and 3MHz probes
  • This system has been modified with incorporation of an AFLink board and associated software that permits capture of raw RF beamformed 3D images frames.

Calendar/Consultation Request for Sonos 7500

If you are interested in reserving the Sonos 7500 ultrasound please check the calendar to verify its availability.

Click here to view the calendar.

iE33 Philips Medical

  • Color Doppler and CW/PW Doppler
  • Tissue Doppler and Tissue Harmonic Imaging
  • Live 3D and Stress Echo
  • 3DQ Quantification
  • Cardiac & Vascular Clinical Option
  • Contrast Imaging with Improved LVO & LVO Tissue Specific Application
  • Panoramic Imaging
  • Strain-Q
  • Live xPlane
  • Netlink/DICOM 3.0 Connectivity
  • Integrated DVD-RW/CD-RW drive
  • This system is equipped with 2 matrix array probes; 1) S5-1 transducer, and 2) X7-2 phased array transducer.
  • This system has been modified with incorporation of an AFLink board and associated software that permits capture of raw RF beamformed 3D images frames.

Calendar/Consultation Request for iE33 Philips Medical

If you are interested in reserving the iE33 Philips Medical ultrasound please check the calendar to verify its availability. 

Click here to view the calendar.

Mouse UltraSound Imaging Core (MUSIC)

Principal Investigator: Lawrence Young, MD

For more information, please download this PDF. 

Visual Sonics Model 2100

  • Superior resolution and image uniformity through entire field of view
  • 30 micron resolution
  • Superb B-Mode (2D) imaging for anatomical visualization and quantification, with enhanced temporal resolution with frame rates up to 740 fps (in 2D for a 4x4 mm FOV) , and enhanced image uniformity with multiple focal zones (included in base package)
  • M-Mode for visualization and quantification of wall motion in cardiovascular research, single line acquisition allows for the very high-temporal (1000 fps) resolution necessary for analysis of LV function
  • Anatomical M-Mode for adjustable anatomical orientation in reconstructed M-Mode imaging; software automatically optimizes field of view for maximum frame rate
  • Pulsed-Wave Doppler Mode (PW) for quantification of blood flow
  • Color Doppler Mode for detection of  blood vessels including flow directional information and mean velocities; as well as for identification of small vessels not visible in B-Mode
  • Power Doppler Mode for detection and quantification of blood flow in small vessels not visible in B-Mode; increased frame rates allow for significantly faster data acquisition
  • Tissue Doppler Mode for quantification of myocardial tissue movement; for example in assessing diastolic dysfunction
  • Vevo MicroMarker® Nonlinear Contrast Agent Imaging – for quantification of relative perfusion & molecular expression of endothelial cell surface markers; enhanced sensitivity to Vevo MicroMarker contrast agents as linear tissue signal is suppressed
  • 3D-Mode Imaging for anatomical and vascular visualization, when combined with either B-Mode, Power Doppler Mode or Nonlinear Contrast Imaging; allows for quantification of volume and vascularity within a defined anatomical structure
  •  Nonlinear Contrast Imaging
  •  VevoStrain™ Analysis software for cardiac research
  •  Advanced measurements & quantification

Calendar/Consultation Request for Visual Sonics Model 2100

If you are interested in reserving the Visual Sonics Model 2100 ultrasound please check the calendar to verify its availability.

Click here to view the calendar.